LPP-T40 - A Success in Lead
Mt Garnet zinc concentrator in Queensland Australia installed an LPP-T40 hose pump to deliver lead slurry to a filter feed tank serving a vertical filter press in the second phase of their expansion. The LPP-T pump allows an in-line installation where suction lines can be significantly shorter. This prevents settling of the heavy lead slurry in the pipeline.
|
Process Conditions
|
|
Specific Gravity
|
2.2
|
|
Solids Content
|
60%
|
|
Temperature
|
40oC
|
|
Medium
|
Lead slurry
|
The new LPP-T operates as a thickener underflow pump. A wide control range is required as the slurry has a typical specific gravity of 2 - 3 but can at times be as high as 5 - 6. The underflow flow rate is 2.2 m3/h. Output is regulated by the inverter controlled LPP-T ensuring optimal thickener operation.
Previously, one of the main problems in the process was the blocking of the suction pipeline at low flow-rates as well as tripping of the inverter due to high friction in low speed control situations. The new LPP-T allows in-line installation and its unique, low friction operating principles at low rpm prevent the VS pump motor from tripping.