Home > News >

LPP-T Pump for Thickener Underflow

One LPP-T65 peristaltic pump is installed to control a thickener underflow. This pump runs at a variable speed to control solids content and feeds the non ferrous metallic fines to a centrifuge for classification and separation.

Process Conditions
Specific Gravity
2.6 to 8.9
Solids Content
50 to 60%
Flow rate
10 –20 m3/h (LPP-T65)
Medium
Non Ferrous Metallic Fines

Controlled by a VFD, the flow rates fluctuates between 9 to 20 m3/hto maintain the solids contents from 50 to 60% to a centrifuge. The LPP pump can also see solids contents up to 85% after shut down periods.

The Larox pump was chosen to replace a centrifugal pump due to its numerous benefits

  • Steady volumetric pumping
  • Ability to handle fluctuations in solids contents
  • Reverse flow capabilities (clear blockage and the injection of water to bottom of thickener to reduce mole holing)
  • Reliability
  • Ease of maintenance

The use of the LPP pump has increased the overall efficiency of the centrifuge process to the increase solids content.



Copyright 2007 Larox Flowsys Oy | Legal | Sitemap | Contact us